Emergency ElectriciansLondon · 24/7 Response

Services & repairs 1

EICR

EICR — 24/7 emergency electricians across London and the M25
07414 254125

An EICR (Electrical Installation Condition Report) is a critical safety assessment designed to ensure that the fixed wiring and electrical components of your property are safe and fit for continued use. Whether you are a homeowner concerned about flickering lights, a landlord meeting legal obligations, or a business owner protecting your staff, this comprehensive formal document provides an essential overview of your electrical infrastructure. Our team operates across London and the M25 corridor, offering detailed inspections to identify hidden hazards before they escalate into dangerous situations.

Neglecting your electrical systems can lead to catastrophic failures, including fires or severe shocks, which is why an EICR is more than just a piece of paperwork; it is a vital safety check. By evaluating the state of your cables, sockets, and consumer units, our electricians can pinpoint deterioration, damage, or non-compliance with current UK safety standards (BS 7671). In an emergency situation where power loss or burning smells occur, an immediate inspection becomes the priority to restore safety and functionality to your property.

What is an EICR?

An Electrical Installation Condition Report is a formal inspection of the internal wiring of a building. Often referred to as 'landlord safety tests' or 'periodic inspections,' this process involves a thorough examination of the circuits, fuse boards, and grounded systems. Unlike a simple visual check, this assessment uses specialist testing equipment to measure the resistance and insulation of wires hidden behind walls and under floors.

During the process, an electrician will look for signs of wear and tear, as well as any signs of DIY electrical work that may not meet regulatory standards. The resulting report classifies the installation with specific codes, ranging from 'Satisfactory' to 'Unsatisfactory,' detailing any remedial works required to bring the property up to a safe standard.

Recognising the Signs You Need an Inspection

While many electrical issues are hidden, there are several red flags that suggest your property is overdue for a professional assessment. If you notice any of these signs, it is important to seek a professional evaluation to prevent further degradation of your system.

Common indicators that your electrical installation may be failing include:

  • —Frequent tripping of circuit breakers or blowing of fuses.
  • —Discolouration or scorch marks around plug sockets and light switches.
  • —A persistent smell of burning plastic or ozone near electrical points.
  • —Flickering or dimming lights when high-power appliances are turned on.
  • —Small shocks or tingling sensations when touching metal appliances.
  • —Visible damage to cables or outdated equipment, such as wooden-backed fuse boxes.

Root Causes of Electrical Deterioration

Electrical systems do not last forever. In London’s diverse range of properties, from Victorian conversions to modern commercial spaces, several factors contribute to the decline of wiring health. Overloading is a primary cause; older systems were never designed to handle the high-load demands of modern kitchens and home offices, leading to heat stress on cables.

Environmental factors also play a role. Dampness in basements or roof leaks can lead to corrosion of terminals, while rodents in ceiling voids may chew through insulation, exposing live conductors. Additionally, general mechanical wear and tear over decades causes connections to loosen, which increases the risk of arcing and subsequent fire hazards.

The Risks of Ignoring Your Electrical Safety

The primary risk of failing to maintain a valid EICR is the threat to life and property. Faulty wiring is one of the leading causes of domestic fires in the UK. Without regular testing, high-resistance faults can generate enough heat to ignite building materials without ever tripping a circuit breaker.

For landlords and business owners, there are also significant legal and financial risks. Failure to provide a safe environment can lead to significant fines and may invalidate your building insurance. In the event of a fire or injury, an outdated or missing report can leave the property owner liable for damages and prosecution under health and safety legislation.

What the Electrician Does During the Test

When our electricians arrive to perform the inspection, they follow a systematic process to ensure every circuit is verified. The process begins with a visual inspection to check for obvious signs of damage or overheating. Following this, a series of 'dead' and 'live' tests are conducted using calibrated instruments.

The professional will perform the following actions:

  • —Continuity testing to ensure all protective conductors are properly connected.
  • —Insulation resistance testing to check that the wire covering is intact.
  • —Polarity checks to confirm that all connections are in the correct sequence.
  • —RCD testing to ensure that safety cut-off switches trip within the required milliseconds.
  • —Verification of earthing and bonding to ensure a safe path for fault currents.

Safety Checks for Property Owners

While a full EICR must be performed by a qualified professional, there are safety checks that homeowners and tenants can perform themselves. You should regularly press the 'Test' or 'T' button on your RCD (Residual Current Device) in the consumer unit. If the power does not cut off immediately, the device is faulty and requires urgent attention.

Safety is paramount. Never attempt to unscrew socket covers or open the consumer unit yourself, as this exposes live components. If you notice water leaking near electrical fittings, do not touch the switches; turn off the main power at the consumer unit if it is safe to do so and call for assistance immediately. If a fire breaks out, evacuate the building and dial 999.

When Does an Electrical Issue Become an Emergency?

While a standard inspection can be scheduled, certain situations require an emergency response to protect the occupants of a building. If you experience a total loss of power that is not a local grid outage, or if you hear loud buzzing or crackling sounds from your fuse box, you should seek immediate help.

An emergency situation also exists if there is a smell of smoke or if a socket has become hot to the touch. In these instances, the electrician will perform focused fault-finding to isolate the danger before recommending a full EICR to ensure the rest of the installation remains stable. If the fault is with the external supply (the service head or street cables), you must contact your local Network Operator by calling 105.

London and M25 Coverage

Our services extend across all London boroughs and into the surrounding areas near the M25. We understand the unique challenges of the capital’s infrastructure, from high-rise apartments to sprawling industrial units. Our 24/7 availability ensures that whether you are in a central city office or a suburban home, expert help is available when you need it most.

By maintaining your electrical records and ensuring your installation meets current BS 7671 standards, you provide peace of mind for yourself and your family. Our reports are clear, concise, and provide the necessary road map for any repairs that may be required.

Related services

Frequently asked questions

How often should an EICR be carried out?

For most domestic properties, it is recommended every 10 years for homeowners. However, for rented properties, it is a legal requirement to have an inspection every 5 years or at the start of a new tenancy. Commercial buildings usually require testing every 5 years.

How long does a typical inspection take?

The duration depends on the size of the property and the number of circuits. A small flat might take 2-3 hours, while a large family home or commercial premises can take a full day or longer to inspect thoroughly.

Will the power be turned off during the test?

Yes, the electricity will need to be turned off for short periods while 'dead' tests are performed on the circuits. Our electricians will work to minimize disruption and will inform you before switching the power off.

What happens if my report says 'Unsatisfactory'?

If the report identifies C1 (Danger present) or C2 (Potentially dangerous) codes, the installation is deemed unsatisfactory. You must have remedial work carried out to rectify these issues to ensure the safety of the property and its occupants.

Is an EICR the same as a PAT test?

No. An EICR covers the fixed wiring and permanent installations of a building, such as sockets, lights, and the fuse board. PAT (Portable Appliance Testing) only covers plug-in items like kettles, laptops, and power tools.

Call now · 07414 254125Book online